Hermes 88f1d4a414 [glm-grade=A] fix(monitoring): DC-090 outage incidents follow displayed hysteresis status
checkForIncidents compared raw probe transitions while the dashboard badge
(DC-086) follows post-hysteresis displayed status. A single raw down blip
between two ups opened AND resolved a critical outage incident; a suppressed
up blip during a real outage resolved it early. Incidents now open/resolve
on displayed-vs-displayed transitions; previousDisplayed=null keeps legacy
raw semantics for direct callers. 6 new parity tests + legacy checkService
test moved to a 4-probe chain. Suite 2616/2616 (110).